Model: 825RL0126

Electromagnetic Relay

Properties:

Overall Length
3.062 inches
Center To Center Distance Between Mounting Facilities Parallel To Length
2.375 inches single mounting facility
Overall Height
2.781 inches
Overall Width
2.031 inches
Case Material
Metal
Environmental Protection
Hermetic
Unthreaded Mounting Hole Diameter
0.218 inches single mounting facility
Fragility Factor
Moderately rugged
Winding Quantity
1
Purpose For Which Designed
General
Coil Quantity
1
Winding Dc Resistance Rating
59.0 ohms single winding
Duty Type
Continuous
Arc Quenching Method
Air
Mounting Facility Type And Quantity
2 unthreaded hole single mounting facility
Storage Type
General purpose warehouse
Cubic Measure
17.294 cubic inches
Mounting Facility Pattern
In-line single mounting facility
Nonpile-up Main Contact Arrangement
2 pole, single throw, normally open, double make, momentary action
Time Delay
0.01 seconds fixed release time
Time Delay
0.03 seconds fixed operate time
Operating Voltage Rating And Type At Specificationified Temp
28.0 volts dc 25 degrees celsius single winding
Main Contact Load Current Rating At Maximum Rated Voltage
35.0 amperes ac motor load and 40.0 amperes dc motor load
Main Contact Load Current Rating At Maximum Rated Voltage
40.0 amperes dc inductive load
Main Contact Load Current Rating At Maximum Rated Voltage
55.0 amperes ac resistive load and 55.0 amperes dc resistive load
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity
6 threaded stud all functions
Specification Data
96906-ms24178 government standard
NSN
5945-00-729-1358
Part Number
825RL0126
Description
Relay,electromagnetic
CAGE

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

Part 825RL0126 NSN 5945-00-729-1358

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
32512
FIIG:
A03300
Concept No.:
1
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
MMAC:
EH
CRITL:
X

Packaging & Shipping

Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
3.1 X 2.0 X 2.8
Paclk Weight:
0.8000lbs
Item Weight:
--
Item Dim:
--
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Q
LVL_B:
Q

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
77.5
WCC:
72D
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this electromagnetic relay (NSN 5945-00-729-1358) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »

New Products Recently updated in relays and solenoids

  • 408-1096-00 electromagnetic relay
    NSN 5945-00-084-3430

    2a single mounting facility thread class, 0.820 inches overall length, 0.412 inches single mounting facility center to center distance between mounting facilities parallel to length

  • 5430-1HS electromagnetic relay
    NSN 5945-00-084-3444

    Relay

  • 408-1086-00 electromagnetic relay
    NSN 5945-00-084-3462

    2a single mounting facility thread class, 1.000 inches overall length, 0.500 inches single mounting facility center to center distance between mounting facilities parallel to length

  • 974-0757-00 electromagnetic relay
    NSN 5945-00-084-3474

    2a single mounting facility thread class, 1.656 inches overall length, 1.406 inches single mounting facility center to center distance between mounting facilities parallel to length

  • 974-0802-00 electromagnetic relay
    NSN 5945-00-084-3480

    1.320 inches overall length, 1.078 inches single mounting facility center to center distance between mounting facilities parallel to length

  • 2243215-001 electromagnetic relay
    NSN 5945-00-084-3666

    1.320 inches overall length, 1.078 inches single mounting facility center to center distance between mounting facilities parallel to length

Schedule B and Export
  • Schedule B: 8536490075
  • SITC: 77254
  • End Use: Electric apparatus
  • NAICS: 335314
  • USDA: 1

Freight Class: Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v, nesoi

Highest Rated Parts
Recently Purchased Parts
Hot Parts