Model: 583-G111-J3M1-C4S1U-5A

Circuit Breaker

Properties:

Body Style
Multipole-single actuator type
Pole Quantity
3
Mounting Facility Type And Quantity
1 threaded bushing
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations and 5.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac all locations and 28.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac all locations and 6000.0 dc all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Thermal all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Internal Trip Release Configuration
Series trip all locations
Thread Size
6.0 millimeters
Inclosure Protection Type For Which Designed
Humidity resistant and shock resistant and vibration resistant
Trip Release Ambient Tempurature Rating
-55.0 degrees celsius all locations and 90.0 degrees celsius all locations
Part Name Assigned By Controlling Agency
High performance thermal circuit breaker
Frequency In Hertz
400.0 all locations
Supplementary Features
Item has auxiliary contact (n/c) (connector to en 3155-016m2018, size 20); barrier included (19.5 wide and 37.7 long-both mm; volt drop per pole 260mv
Thread Series Designator
Unc
Terminal Type And Quantity
6 screw
NSN
5925-01-582-4346
Part Number
583-G111-J3M1-C4S1U-5A
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part 583-G111-J3M1-C4S1U-5A NSN 5925-01-582-4346

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
A
ESD:
A
ESD:
A
MMAC:
CRITL:
X

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-01-582-4346) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi