NSN 6525-01-012-7383

Medical X-ray Apparatu Tube Unit
DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
010127383

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

Product Definition Definition of approved item name (AIN): "TUBE UNIT,MEDICAL X-RAY APPARATU"

Consists of a tube insert in a suitable housing equipped with cable receptacles; without cables.

6525-01-012-7383 Spec. NSN part characteristics

MRC
Name
Detail
MRC:
ALQG
Container Type
Any acceptable
MRC:
CLPJ
Tube Insert Anode Type
High speed rotating
MRC:
CLPL
Tube Insert Radiographic Peak Voltage Rating
150.0 kilovolts
MRC:
CLPP
Focal Spot Quantity
2
MRC:
CLPQ
Focal Spot Size
0.6 mm sq; 1.2 mm sq
MRC:
CMGS
Housing X-ray Protective Value
X-ray protective value of housing shall be in accordance with dhew publication no. Fda 75-8003 jul 1974
MRC:
CQTT
Target Base Material
Molybdenum
MRC:
CQWH
Target Angle In Deg
12.0
MRC:
CSJQ
Target Face Material
Tungsten-rhenium alloy
MRC:
CTBN
Port To Cable Receptacle Angle In Deg
270.0
MRC:
CTGC
Anode Heat Capacity Rating In Heat Units
300000
MRC:
CXCY
Part Name Assigned By Controlling Agency
Tube unit medical x-ray apparatus focal spot size 0.6; 1.2mm sq

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
652500C959057
Cage Code:
81923
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:
Part Number:
S30843
Cage Code:
37480
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:
Indicates a design/source control reference item
Inidicates part number has been superseded

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
15750
FIIG:
T140-C
Concept No.:
App. Key:
CB
Cond. Code:
1
Status:
A

Special material and handling

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.