NSN 5945-00-060-5278

Electromagnetic Relay
DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
000605278

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

Inventory

 

This product may be available in the following quantities and conditions.

  • NE: 555
  • NS: 40
  • AR: 1

Please note that inventory for this NSN was updated 08/29/2024 and may have changed since then. Request a quote for up to date pricing and availability.

Product Definition Definition of approved item name (AIN): "RELAY,ELECTROMAGNETIC"

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

Major End Items End items to which 5945-00-060-5278 is a component of

  • ATQ An/glq 3 Countermeasure Set
  • N/A Radar Set Control
  • N/A Digital Timer
  • N/A Air Data Computer
  • N/A Powerxdistribution
  • N/A Signal Generator
  • N/A Audio Switc Control
  • N/A Guided Missile Launching Station Test Set
  • N/A Fire Control System Test Set
  • N/A C Decoder Simulator
  • N/A Test Set Module Nav
  • N/A Receiver Test Panel
  • N/A Electronic Control Amplifier

5945-00-060-5278 Spec. NSN part characteristics

MRC
Name
Detail
MRC:
ABHP
Overall Length
1.840 inches
MRC:
ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length
1.406 inches single mounting facility
MRC:
ABKW
Overall Height
1.130 inches
MRC:
ABMK
Overall Width
1.660 inches
MRC:
ADZC
Environmental Protection
Hermetic
MRC:
AEBV
Unthreaded Mounting Hole Diameter
0.152 inches single mounting facility
MRC:
AKDX
Winding Quantity
1
MRC:
APCN
Coil Quantity
1
MRC:
APNA
Winding Dc Resistance Rating
240.0 ohms single winding
MRC:
APNP
Duty Type
Continuous
MRC:
AXHR
Mounting Facility Type And Quantity
2 unthreaded hole single mounting facility
MRC:
CQYJ
Mounting Facility Pattern
In-line single mounting facility
MRC:
CRNG
Nonpile-up Main Contact Arrangement
4 pole, double throw, one position momentary
MRC:
CRPQ
Operating Current Rating And Type
110.0 milliamperes dc single winding
MRC:
CSXF
Operating Voltage Rating And Type At Specificationified Temp
26.5 volts dc 25 degrees celsius single winding
MRC:
CTDL
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes dc resistive load
MRC:
CWAB
Main Contact Maximum Voltage Rating In Volts
28.0 dc
MRC:
TTQY
Terminal Type And Quantity
14 pin all functions

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
M5757/7-001
Cage Code:
81349
RNCC:
2
RNVC:
2
DAC:
3
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
MILR5757-7
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
3
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
4170600-020
Cage Code:
05869
RNCC:
C
RNVC:
1
DAC:
6
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
FC-4-250
Cage Code:
53655
RNCC:
C
RNVC:
1
DAC:
6
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
FC-4-250
Cage Code:
81412
RNCC:
C
RNVC:
1
DAC:
6
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
GR835AK1
Cage Code:
26512
RNCC:
E
RNVC:
8
DAC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
WMRX4005
Cage Code:
02288
RNCC:
E
RNVC:
8
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
1068006
Cage Code:
53711
RNCC:
E
RNVC:
8
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
1068006
Cage Code:
77342
RNCC:
E
RNVC:
8
DAC:
6
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
350-35049
Cage Code:
99699
RNCC:
E
RNVC:
8
DAC:
6
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
FC-4-250
Cage Code:
78290
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
RY4LB3B3L01
Cage Code:
81349
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
RY4L1B3L0
Cage Code:
81349
RNCC:
5
RNVC:
9
DAC:
E
RNAAC:
TU
Status:
A
MSDS:
SADC:
Indicates a design/source control reference item
Inidicates part number has been superseded

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
32512
FIIG:
A03300
Concept No.:
1
App. Key:
A
Cond. Code:
1
Status:
A

Special material and handling

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Import and Export

Schedule B
NAIC
End Use
SITC
USDA
HITECH
Schedule B:
8536410020
NAICS:
335314
End Use Class:
20005
SITC:
77254
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8536410020

Relays, Electromechanical, With Contacts Rated Less Than 10 A, For A Voltage Not Exceeding 60 V

End Use Code 20005

Electric Apparatus

Standard Intl. Trade Class (SITC) 77254

Relays For Electrical Apparatus Used With Electrical Circuits Not Exceeding 1, 000 Volts

National motor freight and handling

NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
061300
NMF Description:
Circuit Breaker/switch Noi
UFC:
34410
LTL:
77.5
LCL:
77.5
WCC:
72D
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 72D

Communications/electronics, other than sigint/ew or comsec repair parts and components.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)