NSN 5935-00-005-6981

Electrical Plug Connector Description: Moisture resistant and salt water resistant and vibration resistant, Thread Length: 0.531", Thread Size: 2.125-2.25"  |  Minimum order quantity: 1 Ea
DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
EA
NIIN:
000056981

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

Q & A

Product Definition Definition of approved item name (AIN): "Electrical Plug Connector"

An electrical fitting with electrical contacts, constructed to be affixed to the end of a cable, conduit, coaxial line, cord or wiring for convenience in joining with other electrical connector(s) or printed wiring board and is not designed to be mounted on a bulkhead, chasses, panel, printed wiring board, or the like. Excludes jack, telephone; jack, tip; plug, telephone; plug tip; insert, electrical connector; connector body (as modified); and socket, plug-in, electronic components. see also lead assembly, electrical; wiring harness (as modified); and cable assembly (as modified). for items without inserts, see shell, electrical connector.

5935-00-005-6981 Spec. NSN part characteristics

moisture resistant and salt water resistant and vibration resistant thread length 0.531 thread size 2.125-2.25

MRC
Name
Detail
MRC:
PMLC
Precious Material And Location
Contact surfaces gold
MRC:
PRMT
Precious Material
Gold
MRC:
TEST
Test Data Document
81349-mil-c-83723 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
MRC:
CXCG
Included Contact Quantity
7 single mating end 1st contact grouping
MRC:
CXCL
Included Contact Type
Round pin single mating end all contact groupings
MRC:
AAJF
Thread Direction
Right-hand and right-hand
MRC:
AAJD
Thread Class
2a and 2b
MRC:
ADAV
Overall Diameter
2.464 inches maximum
MRC:
ADZC
Environmental Protection
Moisture resistant and salt water resistant and vibration resistant
MRC:
AAQL
Body Style
Straight shape, internal coupling
MRC:
ABHP
Overall Length
1.842 inches maximum
MRC:
AFQR
Threaded Device Type
Back shell and coupling facility
MRC:
AFQW
Mating End Quantity
1
MRC:
AFQX
Contact Position Arrangement Style
36-7 single mating end
MRC:
AFQZ
Contact Removability
Removable single mating end all contact groupings
MRC:
AFRC
Contact Maximum Current Rating In Amps
22 single mating end 2nd contact grouping
MRC:
AFRC
Contact Maximum Current Rating In Amps
41 single mating end 1st contact grouping
MRC:
AFRE
Contact Maximum Dc Voltage Rating In Volts
700 single mating end all contact groupings
MRC:
AFRN
Polarization Method
Keyway or multiple keyway
MRC:
AFRD
Contact Maximum Ac Voltage Rating In Volts
500 single mating end all contact groupings
MRC:
AFRT
Shell Type
Solid
MRC:
AFRP
Insert Position In Deg
0
MRC:
CMLP
Thread Quantity Per Inch
16 and 16
MRC:
AKMG
Nominal Thread Length
0.531 inches
MRC:
AFRV
Connector Locking Method
Internally threaded coupling ring
MRC:
CQTM
Terminal Location
Back single mating end all contact groupings
MRC:
CQJX
Nominal Thread Size
2.125 inches and 2.25 inches
MRC:
CQTZ
Contact Material
Copper alloy single mating end all contact groupings
MRC:
CQYH
Contact Surface Treatment
Gold single mating end all contact groupings
MRC:
THSD
Thread Series Designator
Un and un
MRC:
CRBJ
Contact Surface Treatment Document And Classification
Mil-g-45204, type 2, class 1 mil spec single treatment response single mating end all contact groupings
MRC:
CTHH
Shell Material Document And Classification
Qq-a-367 fed spec single material response and qq-a-225 fed spec 2nd material response or qq-a591 fed spec 3rd material response
MRC:
CSCF
Terminal Type
Crimp single mating end all contact groupings
MRC:
CSPT
Shell Material
Aluminum alloy
MRC:
CXCG
Included Contact Quantity
40 single mating end 2nd contact grouping
MRC:
ZZZK
Specification/standard Data
81349-milc83723/24 government specification

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
M83723/24R3607N
Cage Code:
81349
RNCC:
2
RNVC:
2
DAC:
3
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
MILC83723-24
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
3
RNAAC:
TX
Status:
A
MSDS:
SADC:
Indicates a design/source control reference item
Inidicates part number has been superseded

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
01938
FIIG:
A039B0
Concept No.:
App. Key:
G
Cond. Code:
1
Status:
A

Special material and handling

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
G
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) G

Item contains gold.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Import and Export

Schedule B
NAIC
End Use
SITC
USDA
HITECH
Schedule B:
8536695050
NAICS:
335931
End Use Class:
20005
SITC:
77258
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8536695050

Electrical Plugs & Sockets, For A Voltage Not Exceeding 1, 000 V, Nesoi

End Use Code 20005

Electric Apparatus

Standard Intl. Trade Class (SITC) 77258

Electric Plugs and Sockets, For Voltages Not Exceeding 1, 000 Volts

National motor freight and handling

NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
061680
NMF Description:
Elec Wiring Plugs Etc
UFC:
34570
LTL:
Rating variable
LCL:
--
WCC:
658
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 658

Electrical appliances, small.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)