NSN 5925-00-272-7002

Circuit Breaker
DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
--
NIIN:
002727002

Pricing & Availability

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

Product Definition Definition of approved item name (AIN): "CIRCUIT BREAKER"

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

5925-00-272-7002 Spec. NSN part characteristics

MRC
Name
Detail
MRC:
AAQL
Body Style
Single pole type
MRC:
ABHP
Overall Length
3.156 inches
MRC:
ADAT
Body Width
1.875 inches
MRC:
ADTV
Case Material
Plastic
MRC:
AEBP
Center To Center Distance Between Terminals Parallel To Length
1.062 inches
MRC:
AEBV
Unthreaded Mounting Hole Diameter
0.250 inches
MRC:
AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.406 inches
MRC:
AJWX
Mounting Surface To Terminal End Distance
1.640 inches
MRC:
AKPX
Pole Quantity
1
MRC:
AXHR
Mounting Facility Type And Quantity
2 unthreaded hole
MRC:
BBRG
Storage Type
General purpose warehouse
MRC:
CPLM
Maximum Continuous Load Current Rating Per Pole
105.0 amperes dc single location
MRC:
CPRF
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
MRC:
CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 dc single location
MRC:
CPRH
Circuit Protection Type
Overcurrent single location
MRC:
CPRJ
Trip Release Method
Thermal single location
MRC:
CPRL
Trip Release Characteristic
Time delay single location
MRC:
CPRN
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
MRC:
CPRQ
Reset Method
Manual
MRC:
CPRR
Main Contact Tripping Mechanism Type
Trip free
MRC:
CPRT
Manual Actuator Type And Quantity
1 push button
MRC:
CPRW
Actuator Function
Reset
MRC:
CPRX
Actuator Position Designation
At pole one
MRC:
CPSM
Internal Trip Release Configuration
Series trip single location
MRC:
CQWN
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 at 200 pct single location and 50.000 at 200 pct single location
MRC:
CQXF
Inclosure Protection Type For Which Designed
Dustproof and weatherproof
MRC:
CRCF
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location
MRC:
TTQY
Terminal Type And Quantity
2 threaded stud

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
PDLMS105
Cage Code:
82647
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
PLMS105
Cage Code:
82647
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Indicates a design/source control reference item
Inidicates part number has been superseded

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Special material and handling

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.