NSN 5925-00-271-8836

Circuit Breaker
DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
--
NIIN:
002718836

Pricing & Availability

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

Product Definition Definition of approved item name (AIN): "CIRCUIT BREAKER"

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

5925-00-271-8836 Spec. NSN part characteristics

MRC
Name
Detail
MRC:
ABHP
Overall Length
6.000 inches
MRC:
ABKW
Overall Height
3.969 inches
MRC:
ABMK
Overall Width
1.375 inches
MRC:
ADTV
Case Material
Plastic
MRC:
AEBV
Unthreaded Mounting Hole Diameter
0.188 inches
MRC:
AKPX
Pole Quantity
1
MRC:
APNQ
Arc Quenching Method
Deion
MRC:
AXHR
Mounting Facility Type And Quantity
2 unthreaded hole
MRC:
CPLM
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac single location and 25.0 amperes dc single location
MRC:
CPRF
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 125.0 dc single location
MRC:
CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location and 5000.0 dc single location
MRC:
CPRH
Circuit Protection Type
Overcurrent single location
MRC:
CPRJ
Trip Release Method
Thermal-magnetic single location
MRC:
CPRL
Trip Release Characteristic
Instantaneous single location and time delay single location
MRC:
CPRN
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
120.0 single location
MRC:
CPRQ
Reset Method
Manual
MRC:
CPRR
Main Contact Tripping Mechanism Type
Trip free
MRC:
CPRT
Manual Actuator Type And Quantity
1 toggle
MRC:
CPRW
Actuator Function
Trip w/separate reset
MRC:
CQWN
Trip Delay Time In Seconds Per Rated Continuous Current
2600.000 at 125 pct single location and 75.000 at 200 pct single location and 24.000 at 300 pct single location
MRC:
CRCF
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location
MRC:
FEAT
Special Features
Mtg holes diagonally spaced 0.812 by 4.844 in c to c
MRC:
FREQ
Frequency In Hertz
60.0 single location
MRC:
PRMT
Precious Material
Silver
MRC:
TTQY
Terminal Type And Quantity
2 screw

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
0A115279-6
Cage Code:
23667
RNCC:
3
RNVC:
9
DAC:
5
RNAAC:
48
Status:
A
MSDS:
SADC:
Part Number:
0A115279-6
Cage Code:
06840
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
48
Status:
A
MSDS:
SADC:
Indicates a design/source control reference item
Inidicates part number has been superseded

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Special material and handling

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
S
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) S

Item contains silver.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.