NSN 5925-00-007-0613

Breaker Description: Body Length: up to 1.5 inches, Frequency In Hertz: 400 all locations, Body Width: 1.25 inches, Mounting Surface To Terminal End Distance: up to 1.78 inches  |  Minimum order quantity: 1 EA
DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
000070613

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

Q & A

Product Definition Definition of approved item name (AIN): "Breaker"

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

5925-00-007-0613 Spec. NSN part characteristics

body length: up to 1.5 inches frequency in hertz: 400 all locations body width: 1.25 inches mounting surface to terminal end distance: up to 1.78 inches

MRC
Name
Detail
MRC:
CPRX
Internal Trip Release Configuration
Series trip first location
MRC:
CPRW
Actuator Position Designation
Between pole one and two
MRC:
CPRT
Actuator Function
Trip-reset
MRC:
CPRR
Manual Actuator Type And Quantity
1 toggle
MRC:
CPRQ
Main Contact Tripping Mechanism Type
Trip free
MRC:
CPRN
Reset Method
Manual
MRC:
CPRL
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115 all locations
MRC:
CPRJ
Trip Release Characteristic
Time delay all locations
MRC:
CPRH
Trip Release Method
Magnetic-hydraulic all locations
MRC:
CPRG
Circuit Protection Type
Overcurrent all locations
MRC:
CPRF
Highest Interrupting Capacity Current Type And Rating Per Pole In Amps
1000 ac all locations
MRC:
CPLM
Operating Voltage Type And Rating Per Pole In Volts
240 ac all locations
MRC:
CMLP
Highest Continuous Load Current Rating Per Pole
3 amperes ac all locations
MRC:
BBRG
Thread Quantity Per Inch
32
MRC:
AXHR
Storage Type
General purpose warehouse
MRC:
AJWX
Pole Quantity
2
MRC:
AKPX
Mounting Facility Type And Quantity
1 threaded bushing
MRC:
AEBQ
Mounting Surface To Terminal End Distance
Up to 1.78 inches
MRC:
AEBP
Center To Center Distance Between Terminals Parallel To Width
0.625 inches
MRC:
ADAQ
Body Width
Up to 1.25 inches
MRC:
ADAT
Case Material
Metal
MRC:
ADTV
Center To Center Distance Between Terminals Parallel To Length
0.875 inches
MRC:
ABXD
Body Length
Up to 1.5 inches
MRC:
AAQL
Bushing Length
Up to 0.38 inches
MRC:
AAQL
Body Style
Multipole-single actuator type
MRC:
CPSM
Internal Trip Release Configuration
Relay trip second location
MRC:
CPSM
Nominal Thread Size
0.375 inches
MRC:
CQJX
Trip Delay Time In Seconds Per Rated Continuous Current
0.005 minimum at 200 pct all locations and 0.017 maximum at 200 pct all locations
MRC:
CQWN
Trip Delay Time In Seconds Per Rated Continuous Current
0.005 minimum at 200 pct and 0.017 maximum at 200 pct all locations
MRC:
CQWN
Inclosure Protection Type For Which Designed
Hermetically sealed
MRC:
CQXF
Frequency In Hertz
400 all locations
MRC:
FREQ
Thread Series Designator
Unef
MRC:
THSD
Terminal Type And Quantity
6 wire hook

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
SM-A-587932-1
Cage Code:
80063
RNCC:
3
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
AP14-1768-1
Cage Code:
81541
RNCC:
5
RNVC:
2
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Indicates a design/source control reference item
Inidicates part number has been superseded

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Special material and handling

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Import and Export

Schedule B
NAIC
End Use
SITC
USDA
HITECH
Schedule B:
8536200040
NAICS:
335313
End Use Class:
20005
SITC:
77252
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8536200040

Automatic Circuit Breakers, For A Voltage Not Exceeding 1, 000 V, Nesoi

End Use Code 20005

Electric Apparatus

Standard Intl. Trade Class (SITC) 77252

Automatic Circuit Breakers For A Voltage Not Exceeding 1, 000 Volts

National motor freight and handling

NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
061300
NMF Description:
Circuit Breaker/switch Noi
UFC:
34410
LTL:
77.5
LCL:
--
WCC:
658
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 658

Electrical appliances, small.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)