Model: TEB122100

Circuit Breaker

Special Features:

Without line lugs

Properties:

Body Style
Multipole-single actuator type
Body Length
6.3125 inches
Body Width
2.750 inches
Body Height
3.1875 inches
Case Material
Plastic
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.87501 inches
Boss Height
0.90625 inches
Pole Quantity
2
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations and 100.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 125.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations and 5000.0 dc all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Thermal-magnetic all locations
Trip Release Characteristic
Instantaneous all locations and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Reset
Trip Delay Time In Seconds Per Rated Continuous Current
89.000 at 200 pct all locations and 370.000 at 200 pct all locations and 35.000 at 300 pct all locations and 120.000 at 300 pct all locations and 18.000 at 400 pct all locations and 60.000 at 400 pct all locations and 12.000 at 500 pct all locations and 36.000 at 500 pct all locations and 9.000 at 1000 pct all locations
Trip Release Ambient Tempurature Rating
10.0 degrees celsius all locations and 50.0 degrees celsius all locations
Frequency In Hertz
60.0 all locations
Supplementary Features
Operating voltage type and rating per pole in volts 250.0 dc in addition to cprf
NSN
5925-01-028-9336
Part Number
TEB122100
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part TEB122100 NSN 5925-01-028-9336

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
MMAC:
CRITL:
X

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-01-028-9336) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi