Model: SM-A-838525-9

Circuit Breaker

Special Features:

High inrush pole one only

Properties:

Thread Pitch Diameters
+0.1177/+0.1214 inches
Body Length
Between 2.480 inches and 2.520 inches
Body Width
Between 1.480 inches and 1.520 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
Between 1.928 inches and 1.948 inches
Center To Center Distance Between Terminals Parallel To Width
Between 0.740 inches and 0.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.052 inches and 2.072 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.740 inches and 0.760 inches
Fragility Factor
Moderately rugged
Boss Height
Between 0.130 inches and 0.150 inches
Mounting Surface To Terminal End Distance
3.450 inches
Pole Quantity
2
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
4 threaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Features Provided
High inrush protection
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc first location
Operating Voltage Type And Rating Per Pole In Volts
35.0 dc second location
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Instantaneous second location
Trip Release Characteristic
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
2 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One and two linked
Internal Trip Release Configuration
Series trip all locations
Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct all locations and 1.500 at 200 pct all locations
Inclosure Protection Type For Which Designed
Shock resistant and fungus proof
Criticality Code Justification
Feat
Unpackaged Unit Weight
6.500 ounces
Test Data Document
80063-sm-a-838525 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
Unc
Terminal Type And Quantity
4 threaded stud
NSN
5925-01-263-2794
Part Number
SM-A-838525-9
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part SM-A-838525-9 NSN 5925-01-263-2794

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
MMAC:
CRITL:
Y

Packaging & Shipping

Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
0.4000lbs
Item Weight:
--
Item Dim:
--
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
--
WCC:
658
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-01-263-2794) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi

Highest Rated Parts
Recently Purchased Parts
Hot Parts