Model: SM336

Circuit Breaker
Description:

Multipole-single actuator type body style, 0.375 inches bushing length, 1.495 inches body length, 1.872 inches body width, metal case material.

Properties:

Body Style
Multipole-single actuator type
Bushing Length
0.375 inches
Body Length
1.495 inches
Body Width
1.872 inches
Case Material
Metal
Center To Center Distance Between Terminals Parallel To Length
0.875 inches
Center To Center Distance Between Terminals Parallel To Width
0.625 inches
Nonturn Device Location
At 3 oclock and at 9 oclock
Nonturn Device Radius
Between 0.620 inches and 0.630 inches
Nonturn Device Diameter
0.138 inches
Fragility Factor
Moderately rugged
Mounting Surface To Terminal End Distance
1.678 inches
Pole Quantity
3
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac first location and 50.0 milliamperes dc first location
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac second location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location and 10.0 dc first location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac first location and 500.0 dc first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac second location
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic-hydraulic all locations
Trip Release Characteristic
Instantaneous first location
Trip Release Characteristic
Time delay second location
Trip Release Characteristic
Time delay third location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole two
Internal Trip Release Configuration
Series trip all locations
Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 at 200 pct second location and 4.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 at 200 pct third location and 4.000 at 200 pct third location
Inclosure Protection Type For Which Designed
Fungus resistant and hermetically sealed and moisture resistant
Frequency In Hertz
60.0 all locations
Unpackaged Unit Weight
4.500 ounces
Precious Material And Location
Contact surfaces silver
Precious Material
Silver
Thread Series Designator
Unef
Terminal Type And Quantity
6 wire hook
NSN
5925-00-136-6935
Part Number
SM336
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part SM336 NSN 5925-00-136-6935

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
S
ESD:
ESD:
MMAC:
EH
CRITL:
X

Packaging & Shipping

Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
0.3000lbs
Item Weight:
--
Item Dim:
--
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
--
WCC:
658
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-00-136-6935) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi