Model: NZM6B-100/ZM6-100-800-OBI-CNA/C-

Circuit Breaker

Properties:

Body Style
Rectangular dimensional envelope
Overall Length
210.0 millimeters
Overall Height
110.0 millimeters
Overall Width
180.0 millimeters
Case Material
Plastic
Fragility Factor
Moderately rugged
Pole Quantity
3
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
6 terminal
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Features Provided
Adjustable trip release and current limiter
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
800.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
14000.0 ac all locations
Circuit Protection Type
Undervoltage all locations
Trip Release Method
Thermal all locations
Trip Release Characteristic
Instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 rotary
Actuator Function
Trip-reset
Actuator Position Designation
Between pole one and two
Adjustable Trip Setting Current Range Per Pole In Amps
+400.0/+800.0 ac all locations
Internal Trip Release Configuration
Series trip all locations
Inclosure Protection Type For Which Designed
General purpose
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations
Extra Long Reference Number
Nzm6b-100/zm6-100-800-obi-cna/cl6
Frequency In Hertz
60.0 all locations
Terminal Type And Quantity
6 compression
Reference Number Differentiating Characteristics
As differentiated by extra long reference number
NSN
5925-01-317-0486
Part Number
NZM6B-100/ZM6-100-800-OBI-CNA/C-
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part NZM6B-100/ZM6-100-800-OBI-CNA/C- NSN 5925-01-317-0486

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
MMAC:
CRITL:
X

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
--
WCC:
658
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-01-317-0486) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi

Highest Rated Parts
Recently Purchased Parts
Hot Parts