Model: MB-1544
Band Pass Filter
Special Features:
Six filtered functions
Properties:
Overall Height
0.750 inches
Vibration Resistance Range In Hertz
+10.0/+2000.0
Operating Tempurature Range
-29.0/+85.0 degrees celsius
Reference Frequency Per Function
11.2 single radio interference pulses per second
Reference Frequency Per Function
14.4 single radio interference two phase to two phase
Reference Frequency Per Function
17.6 single radio interference two phase to three phase
Reference Frequency Per Function
20.8 single radio interference hertz
Reference Frequency Per Function
24.0 single radio interference three phase to two phase
Reference Frequency Per Function
27.2 single radio interference gigahertz
Source Impedance Rating Per Function
1.0 kilohms 3rd band pass
Source Impedance Rating Per Function
1.0 kilohms 4th band pass
Source Impedance Rating Per Function
1.0 kilohms 5th band pass
Source Impedance Rating Per Function
1.0 kilohms 6th band pass
Source Impedance Rating Per Function
1.0 kilohms 1st band pass
Source Impedance Rating Per Function
1.0 kilohms 2nd band pass
Load Impedance Per Function
100.0 kilohms 1st band pass
Load Impedance Per Function
100.0 kilohms 2nd band pass
Load Impedance Per Function
100.0 kilohms 3rd band pass
Load Impedance Per Function
100.0 kilohms 4th band pass
Load Impedance Per Function
100.0 kilohms 5th band pass
Load Impedance Per Function
100.0 kilohms 6th band pass
Inclosure Type
Hermetically sealed
Mounting Facility Type And Quantity
20 pin
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 4th band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 5th band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 6th band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 3rd band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
Functional Terminal Type And Quantity
1 pin ground 3rd function
Functional Terminal Type And Quantity
6 pin input 1st function
Functional Terminal Type And Quantity
6 pin output 2nd function
Specified Frequencies Of Discrimination Per Function
13.70 kilohertz 2nd band pass 2nd function and 13.98 kilohertz 2nd band pass 2nd function and 14.82 kilohertz 2nd band pass 2nd function and 15.10 kilohertz 2nd band pass 2nd function
Specified Frequencies Of Discrimination Per Function
16.77 kilohertz 3rd band pass 3rd function and 17.13 kilohertz 3rd band pass 3rd function and 18.07 kilohertz 3rd band pass 3rd function and 18.43 kilohertz 3rd band pass 3rd function
Specified Frequencies Of Discrimination Per Function
19.86 kilohertz 4th band pass 4th function and 20.28 kilohertz 4th band pass 4th function and 21.32 kilohertz 4th band pass 4th function and 21.74 kilohertz 4th band pass 4th function
Specified Frequencies Of Discrimination Per Function
10.61 kilohertz 1st band pass 1st function and 10.83 kilohertz 1st band pass 1st function and 11.57 kilohertz 1st band pass 1st function and 11.79 kilohertz 1st band pass 1st function
Specified Frequencies Of Discrimination Per Function
22.96 kilohertz 5th band pass 5th function and 23.44 kilohertz 5th band pass 5th function and 24.57 kilohertz 5th band pass 5th function and 25.05 kilohertz 5th band pass 5th function
Specified Frequencies Of Discrimination Per Function
26.05 kilohertz 6th band pass 6th function and 26.59 kilohertz 6th band pass 6th function and 27.81 kilohertz 6th band pass 6th function and 28.35 kilohertz 6th band pass 6th function
Frequency Band Width Per Function
10.83 kilohertz 1st band pass and 11.57 kilohertz 1st band pass
Frequency Band Width Per Function
13.98 kilohertz 2nd band pass and 14.82 kilohertz 2nd band pass
Frequency Band Width Per Function
17.13 kilohertz 3rd band pass and 18.07 kilohertz 3rd band pass
Frequency Band Width Per Function
20.28 kilohertz 4th band pass and 21.32 kilohertz 4th band pass
Frequency Band Width Per Function
23.44 kilohertz 5th band pass and 24.57 kilohertz 5th band pass
Frequency Band Width Per Function
26.59 kilohertz 6th band pass and 27.81 kilohertz 6th band pass
Discrimination At Specificationified Frequencies Per Function In Decibels
3.0 1st band pass 1st function and 30.0 1st band pass 1st function3.0 2nd band pass 2nd function and 30.0 2nd band pass 2nd function3.0 3rd band pass 3rd function and 30.0 3rd band pass 3rd function3.0 4th band pass 4th function and 30.0 4th band pass 4th function3.0 5th band pass 5th function and 30.0 5th band pass 5th function
Body Surface Treatment
Tin
Unpackaged Unit Weight
4.500 ounces
Style Designator
Rectangular terminal/terminals on one surface
Description
Filter,band Pass
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See coil (as modified); reactor; capacitor (as modified); and resistor (as modified).