Model: K646

Power Transformer

Special Features:

One primary winding; eleven secondary windings

Properties:

Reliability Indicator
Not established
Overall Length
1.305 inches
Frequency Rating
50.0 kilohertz single component
Input-output Phase Relationship
Single phase to single phase single component
Maximum Transformer Power Rating
48.0 volt-ampere single component
Body Length
1.055 inches
Body Outside Diameter
1.900 inches
Maximum Operating Temp
130.0 degrees celsius
Inclosure Type
Fully enclosed
Mounting Facility Quantity
1 single group
Mounting Method
Threaded hole single group
Winding Function And Quantity
1 primary single component and 11 secondary single component
Thread Size
0.138 inches single group
Winding Operating Current
1.05 amperes ac single component 1st secondary
Winding Operating Current
100.0 milliamperes ac single component 2nd secondary
Winding Operating Current
470.0 milliamperes ac single component 3rd secondary
Winding Operating Current
25.0 milliamperes ac single component 4th secondary
Winding Power Rating
0.06 volts-amperes single component 4th secondary
Winding Power Rating
0.5 volts-amperes single component 2nd secondary
Winding Power Rating
2.0 volts-amperes single component 3rd secondary
Winding Power Rating
5.9 volts-amperes single component 1st secondary
Winding Operating Voltage
106.05 ac volts single component single primary
Winding Operating Voltage
2.37 ac volts single component 4th secondary
Winding Operating Voltage
4.14 ac volts single component 3rd secondary
Winding Operating Voltage
4.70 ac volts single component 2nd secondary
Winding Operating Voltage
5.62 ac volts single component 1st secondary
Thread Series Designator
Unc single group
Terminal Type And Quantity
24 pin
NSN
5950-01-247-3368
Part Number
K646
Description
Transformer,power
CAGE

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

Part K646 NSN 5950-01-247-3368

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
Concept No.:
1
App. Key:
J
Cond. Code:
2
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
MMAC:
CRITL:
X

Packaging & Shipping

Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
0.5000lbs
Item Weight:
--
Item Dim:
--
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
063420
UFC:
35355
LTL:
RATING VARIABLE
LCL:
--
WCC:
595
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this power transformer (NSN 5950-01-247-3368) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8504314065
  • SITC: 77119
  • End Use: Generators, accessories
  • NAICS: 334416
  • USDA: 1

Freight Class: Transformers, having a power handling capacity 40 va or greater but less than 1 kva, nesoi

Highest Rated Parts
Recently Purchased Parts
Hot Parts