Model: FWC3080JVWA0601

Circuit Breaker

Special Features:

Adj thermal/magnetic trip; w/o terminals

Properties:

Body Style
Multipole-single actuator type
Body Length
152.400 inches
Body Width
70.670 inches
Body Height
85.730 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
119.080 inches
Center To Center Distance Between Terminals Parallel To Width
34.930 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
114.300 inches
Switch Contact Arrangement
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
34.930 inches
End Application
Load ctr 28b ddg91
Boss Height
4.170 inches
Pole Quantity
3
Mounting Facility Type And Quantity
4 threaded hole
Maximum Continuous Load Current Rating Per Pole
80.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
690.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
12000.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Thermal-magnetic all locations
Trip Release Characteristic
Instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
200.0 all locations
Ultimate Trip Time Per Pole In Seconds
4.000 all locations and 20.000 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole two
External Actuator Linkage Arrangement
One, two, and three linked
Auxiliary Switch Function And Quantity
1 control
Thread Size
0.164 inches
Switch Location And Position Designation
Internal at pole one
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations
Switch Terminal Type
Wire lead
Switch Current Rating And Type In Amps
6.0 ac
Frequency In Hertz
50.0 all locations or 60.0 all locations
Thread Series Designator
Unc
NSN
5925-01-513-4408
Part Number
FWC3080JVWA0601
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part FWC3080JVWA0601 NSN 5925-01-513-4408

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
A
ESD:
A
ESD:
A
MMAC:
CRITL:
X

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
--
WCC:
658
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-01-513-4408) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi

Highest Rated Parts
Recently Purchased Parts
Hot Parts