Properties:

Overall Length
1.813 inches
Overall Height
1.093 inches
Overall Width
0.750 inches
Case Material
Plastic
Pole Quantity
1
Arc Quenching Method
Air
Mounting Facility Type And Quantity
1 threaded bushing
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location and 20.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location and 2000.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Magnetic single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
Reset
Thread Size
0.469 inches
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 200 pct single location and 60.000 at 200 pct single location and 3.000 at 300 pct single location and 15.000 at 300 pct single location and 1.500 at 400 pct single location and 6.000 at 400 pct single location
Inclosure Protection Type For Which Designed
Explosion proof
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location
Thread Series Designator
Uns
Terminal Type And Quantity
2 screw
NSN
5925-00-839-4689
Part Number
D6761-1-20
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part D6761-1-20 NSN 5925-00-839-4689

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
MMAC:
CRITL:
X

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
77.5
WCC:
658
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-00-839-4689) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi