Model: AP-7-1R-52-1752

Circuit Breaker

Properties:

Body Style
Single pole type
Bushing Length
0.380 inches
Body Length
1.500 inches
Body Width
0.625 inches
Case Material
Metal
Center To Center Distance Between Terminals Parallel To Length
0.875 inches
Switch Contact Arrangement
Single pole, double throw
Fragility Factor
Moderately rugged
Mounting Surface To Terminal End Distance
1.605 inches
Pole Quantity
1
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
17.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Magnetic single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
Series trip single location
Thread Size
0.375 inches
Switch Location And Position Designation
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
0.850 at 200 pct single location and 4.000 at 200 pct single location
Inclosure Protection Type For Which Designed
Hermetically sealed
Switch Terminal Type
Tab, solder lug
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
Thread Series Designator
Unef
Terminal Type And Quantity
2 tab w/screw
NSN
5925-01-304-0370
Part Number
AP-7-1R-52-1752
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part AP-7-1R-52-1752 NSN 5925-01-304-0370

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
MMAC:
CRITL:
X

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-01-304-0370) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi

Highest Rated Parts