Model: AN3160-10

Circuit Breaker
Description:

Single pole type body style, 2.125 inches body length, 0.750 inches body width, plastic case material, 1.125 inches center to center distance between terminals parallel to length.

Properties:

Body Style
Single pole type
Body Length
2.125 inches
Body Width
0.750 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.125 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.843 inches
Mounting Surface To Terminal End Distance
2.000 inches
Pole Quantity
1
Mounting Facility Type And Quantity
2 threaded bushing
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Thermal single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Nontrip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Internal Trip Release Configuration
Series trip single location
Thread Size
0.138 inches
Reset Actuator Voltage Rating And Type In Volts
30.0 dc
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 200 pct single location and 100.000 at 200 pct single location
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location
Thread Series Designator
Unc
Terminal Type And Quantity
2 screw
NSN
5925-00-153-4507
Part Number
AN3160-10
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part AN3160-10 NSN 5925-00-153-4507

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
MMAC:
CRITL:
X

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
77.5
WCC:
658
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-00-153-4507) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi

Highest Rated Parts
Recently Purchased Parts
Hot Parts