Model: AM12MG6-20A115VACCURVE4

Circuit Breaker
Description:

Single pole type body style, 2.500 inches body length, 0.750 inches body width, plastic case material, 1.938 inches center to center distance between terminals parallel to length.

Properties:

Body Style
Single pole type
Body Length
2.500 inches
Body Width
0.750 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.938 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches
Fragility Factor
Moderately rugged
Boss Height
0.140 inches
Mounting Surface To Terminal End Distance
2.611 inches
Pole Quantity
1
Arc Quenching Method
Air
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
General purpose warehouse
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Magnetic-hydraulic single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Internal Trip Release Configuration
Series trip single location
Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
40.000 at 200 pct single location and 10.000 at 200 pct single location
Inclosure Protection Type For Which Designed
Fungus resistant
Frequency In Hertz
60.0 single location
Thread Series Designator
Unc
Terminal Type And Quantity
2 threaded stud
NSN
5925-00-027-2102
Part Number
AM12MG6-20A115VACCURVE4
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part AM12MG6-20A115VACCURVE4 NSN 5925-00-027-2102

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
Y
PMIC:
U
ESD:
ESD:
MMAC:
CRITL:
N

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-00-027-2102) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi

Highest Rated Parts
Recently Purchased Parts
Hot Parts