Model: A15912-001

Circuit Breaker

Properties:

Body Style
Multipole-multiple actuator type
Body Length
2.530 inches
Body Width
3.060 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.940 inches
Center To Center Distance Between Terminals Parallel To Width
Between 0.750 inches and 0.770 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches
Switch Contact Arrangement
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.750 inches and 0.770 inches
Fragility Factor
Moderately rugged
Boss Height
0.150 inches
Mounting Surface To Terminal End Distance
2.522 inches
Pole Quantity
4
Mounting Facility Type And Quantity
8 threaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic-hydraulic all locations
Trip Release Characteristic
Instantaneous fourth location
Trip Release Characteristic
Time delay second location
Trip Release Characteristic
Time delay third location
Trip Release Characteristic
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
4 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One, two, three, and four linked
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
Relay trip fourth location
Internal Trip Release Configuration
Series trip first location
Internal Trip Release Configuration
Series trip second location
Internal Trip Release Configuration
Series trip third location
Thread Size
0.138 inches
Switch Location And Position Designation
Internal at pole three
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 at 200 pct first location and 5.000 at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 at 200 pct second location and 5.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 at 200 pct third location and 5.000 at 200 pct third location
Inclosure Protection Type For Which Designed
Moisture resistant and fungus resistant and vibration resistant and shock resistant and explosion proof
Switch Terminal Type
Tab, solder lug
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc
Frequency In Hertz
400.0 all locations
Thread Series Designator
Unc
Terminal Type And Quantity
10 threaded stud
Specification Data
12436-a15912 government specification
NSN
5925-00-937-4442
Part Number
A15912-001
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part A15912-001 NSN 5925-00-937-4442

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
MMAC:
CRITL:
X

Packaging & Shipping

Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
--
WCC:
658
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-00-937-4442) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi