Model: 9216

Power Transformer

Special Features:

One primary winding; six secondary windings

Properties:

Reliability Indicator
Not established
Center To Center Distance Between Mounting Facilities Parallel To Length
2.740 inches single mounting facility single center group and 2.760 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.927 inches single mounting facility single center group and 1.947 inches single mounting facility single center group
Overall Width
Between 2.220 inches and 2.280 inches
Mounting Slot Width
0.100 inches single group and 0.160 inches single group
Frequency Rating
400.0 hertz single component
Input-output Phase Relationship
Three phase to three phase single component
Transformer Winding Connection Type
Delta-delta
Maximum Transformer Power Rating
446.5 volt-ampere single component
Winding Shielding Method
Internal shield brought out to terminal single component
Body Length
Between 2.970 inches and 3.030 inches
Body Height
Between 1.280 inches and 1.340 inches
Maximum Operating Temp
155.0 degrees celsius
Inclosure Type
Open
Mounting Facility Quantity
4 single group
Mounting Method
Bracket single group and slot single group
Winding Function And Quantity
1 primary single component and 6 secondary single component
Winding Operating Current
2.5 amperes ac single component 2nd secondary
Winding Operating Current
1.8 amperes ac single component 3rd secondary
Winding Operating Current
900.0 milliamperes ac single component 4th secondary
Winding Operating Current
6.0 amperes ac single component 1st secondary
Winding Power Rating
238.7 volts-amperes single component 1st secondary
Winding Power Rating
24.1 volts-amperes single component 4th secondary
Winding Power Rating
45.4 volts-amperes single component 2nd secondary
Winding Power Rating
48.3 volts-amperes single component 3rd secondary
Winding Operating Voltage
10.50 ac pounds per hour wet single component 2nd secondary
Winding Operating Voltage
15.50 ac pounds per hour wet single component 3rd secondary
Winding Operating Voltage
15.50 ac pounds per hour wet single component 4th secondary
Winding Operating Voltage
113.00 ac pounds per hour dry single component single primary and 195.00 ac pounds per hour with retaining chain single component single primary
Winding Operating Voltage
23.00 ac pounds per hour wet single component 1st secondary
Winding Operating Voltage
113.00 ac volts and 195.00 ac pounds per hour with retaining chain single component single primary
Winding Operating Voltage
10.50 ac volts single component 2nd secondary
Terminal Type And Quantity
22 wire lead
NSN
5950-00-165-3694
Part Number
9216
Description
Transformer,power
CAGE

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

Part 9216 NSN 5950-00-165-3694

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
Concept No.:
1
App. Key:
J
Cond. Code:
2
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
MMAC:
CRITL:
X

Packaging & Shipping

Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
1.0000lbs
Item Weight:
--
Item Dim:
--
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
063420
UFC:
35355
LTL:
RATING VARIABLE
LCL:
--
WCC:
595
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this power transformer (NSN 5950-00-165-3694) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8504314065
  • SITC: 77119
  • End Use: Generators, accessories
  • NAICS: 334416
  • USDA: 1

Freight Class: Transformers, having a power handling capacity 40 va or greater but less than 1 kva, nesoi

Highest Rated Parts
Recently Purchased Parts
Hot Parts