Model: 82P430

Alternating Current Generator

Properties:

Overall Height
90.250 inches
Overall Length
89.500 inches
Overall Width
85.750 inches
Keyway Width
1.500 inches single end
Keyway Depth
0.500 inches single end
Shaft Diameter
6.030 inches single end and 6.035 inches single end
Keyway Length
8.250 inches single end
Shaft Rotation Direction
Clockwise single end
Duty Cycle
Continuous
Inclosure Feature
Totally enclosed
Winding Type
Synchronous
Mounting Method
Fixed base
Mounting Facility Type And Quantity
6 unthreaded hole
Cooling Method
Water-air cooled
Power Rating
2530.000 kilowatts output or 2630.000 kilowatts output
Length Of Shaft From Housing
9.750 inches single end
Connection Type And Voltage Rating In Volts
565.0 line to line low output or 700.0 line to line high output
Shaft End Characteristic
A9 single style single end
Phase
Three output
Frequency In Hertz
73.3 output
Terminal Type And Quantity
8 screw
NSN
6115-01-032-4707
Part Number
82P430
Description
Generator,alternating Current
CAGE

A generator having a characteristic of current and voltage that is continually reversing in direction of flow at regular intervals. Does not include rotary inverters, motor-generators, generator sets, synchros, and frequency or phase changers. Excludes generator, tachometer.

Part 82P430 NSN 6115-01-032-4707

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00781
FIIG:
A271A0
Concept No.:
1
App. Key:
B
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
MMAC:
CRITL:
X

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this alternating current generator (NSN 6115-01-032-4707) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8501640020
  • SITC: 71632
  • End Use: Generators, accessories
  • NAICS: 335312
  • USDA: 1

Freight Class: Ac generators (alternators), output exceeding 750 kva but not exceeding 10,000 kva

Highest Rated Parts
Recently Purchased Parts
Hot Parts