Model: 801840
Multimeter
Properties:
Circuit Current For Which Designed
Dc
Overall Depth
3.125 inches
Overall Length
7.000 inches
Overall Width
5.250 inches
Scale Division Quantity
50 single indicator 1st range50 single indicator 5th range50 single indicator 6th range50 single indicator 7th range50 single indicator 8th range50 single indicator 9th range50 single indicator 10th range50 single indicator 11th range50 single indicator 12th range50 single indicator 13th range50 single indicator 14th range50 single indicator 15th range50 single indicator 16th range
Scale Division Quantity
50 single indicator 10th range
Scale Division Quantity
50 single indicator 11th range
Scale Division Quantity
50 single indicator 12th range
Scale Division Quantity
50 single indicator 13th range
Scale Division Quantity
50 single indicator 14th range
Scale Division Quantity
50 single indicator 15th range
Scale Division Quantity
50 single indicator 16th range
Scale Division Quantity
50 single indicator 1st range
Scale Division Quantity
50 single indicator 5th range
Scale Division Quantity
50 single indicator 6th range
Scale Division Quantity
50 single indicator 7th range
Scale Division Quantity
50 single indicator 8th range
Scale Division Quantity
50 single indicator 9th range
Furnished Items And Quantity
9 v battery 1; 1.5 v battery 1
Indicator Type
Dial w/pointer
Installation Design
Bench
Frequency Response Range
+0.000/+50.000 kilohertz
Frequency Response Range
+0.000 to 50.000 kilohertz
Dial Scale Marking Color
Black single indicator 1st rangeblack single indicator 2nd range and red single indicator 2nd rangeblack single indicator 3rd rangeblack single indicator 4th rangeblack single indicator 5th rangeblack single indicator 6th rangeblack single indicator 7th rangeblack single indicator 8th rangeblack single indicator 9th rangeblack single indicator 10th rangeblack single indicator 11th rangeblack single indicator 12th rangeblack single indicator 13th rangeblack single indicator 14th rangeblack single indicator 15th rangeblack single indicator 16th range
Dial Scale Marking Color
Black and red single indicator 2nd range
Dial Scale Marking Color
Black single indicator 11th range
Dial Scale Marking Color
Black single indicator 12th range
Dial Scale Marking Color
Black single indicator 13th range
Dial Scale Marking Color
Black single indicator 14th range
Dial Scale Marking Color
Black single indicator 15th range
Dial Scale Marking Color
Black single indicator 16th range
Dial Scale Marking Color
Black single indicator 1st range
Dial Scale Marking Color
Black single indicator 10th range
Dial Scale Marking Color
Black single indicator 6th range
Dial Scale Marking Color
Black single indicator 7th range
Dial Scale Marking Color
Black single indicator 8th range
Dial Scale Marking Color
Black single indicator 9th range
Dial Scale Marking Color
Black single indicator 3rd range
Dial Scale Marking Color
Black single indicator 4th range
Dial Scale Marking Color
Black single indicator 5th range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 1st range-2.0/+2.0 at full scale single indicator 2nd range-2.5/+2.5 at full scale single indicator 3rd range-2.5/+2.5 at full scale single indicator 4th range-2.0/+2.0 at full scale single indicator 5th range-2.0/+2.0 at full scale single indicator 6th range-2.0/+2.0 at full scale single indicator 7th range-3.0/+3.0 at full scale single indicator 8th range-3.0/+3.0 at full scale single indicator 9th range-3.0/+3.0 at full scale single indicator 10th range-3.0/+3.0 at full scale single indicator 11th range-2.0/+2.0 at full scale single indicator 12th range-2.0/+2.0 at full scale single indicator 13th range-2.0/+2.0 at full scale single indicator 14th range-2.0/+2.0 at full scale single indicator 15th range-2.0/+2.0 at full scale single indicator 16th range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator 12th range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator 13th range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator 14th range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator 15th range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator 16th range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator 1st range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator 2nd range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator 5th range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator 6th range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator 7th range
Accuracy In Percent
-2.5 to 2.5 at full scale single indicator 3rd range
Accuracy In Percent
-2.5 to 2.5 at full scale single indicator 4th range
Accuracy In Percent
-3.0 to 3.0 at full scale single indicator 10th range
Accuracy In Percent
-3.0 to 3.0 at full scale single indicator 11th range
Accuracy In Percent
-3.0 to 3.0 at full scale single indicator 8th range
Accuracy In Percent
-3.0 to 3.0 at full scale single indicator 9th range
Background Color
White single indicator all ranges
Pointer Color
Black single indicator all ranges
Scale Graduation Type
Linear single indicator 1st rangenonlinear single indicator 2nd rangenonlinear single indicator 3rd rangenonlinear single indicator 4th rangelinear single indicator 5th rangelinear single indicator 6th rangelinear single indicator 7th rangelinear single indicator 8th rangelinear single indicator 9th rangelinear single indicator 10th rangelinear single indicator 11th rangelinear single indicator 12th rangelinear single indicator 13th rangelinear single indicator 14th rangelinear single indicator 15th rangelinear single indicator 16th range
Scale Graduation Type
Linear single indicator 5th range
Scale Graduation Type
Linear single indicator 6th range
Scale Graduation Type
Linear single indicator 7th range
Scale Graduation Type
Linear single indicator 8th range
Scale Graduation Type
Linear single indicator 9th range
Scale Graduation Type
Linear single indicator 10th range
Scale Graduation Type
Linear single indicator 11th range
Scale Graduation Type
Linear single indicator 12th range
Scale Graduation Type
Linear single indicator 13th range
Scale Graduation Type
Linear single indicator 14th range
Scale Graduation Type
Linear single indicator 15th range
Scale Graduation Type
Linear single indicator 16th range
Scale Graduation Type
Linear single indicator 1st range
Scale Graduation Type
Nonlinear single indicator 2nd range
Scale Graduation Type
Nonlinear single indicator 3rd range
Scale Graduation Type
Nonlinear single indicator 4th range
Measurement Range
+0.0/+10.0 amperes, dc single indicator 1st range-20.0/+50.0 decibels single indicator 2nd range+0.0/+200.0 kilohms single indicator 3rd range+0.0/+20.0 megohms single indicator 4th range+0.0/+50.0 microamperes, dc single indicator 5th range+0.0/+100.0 milliamperes, dc single indicator 6th range+0.0/+500.0 milliamperes, dc single indicator 7th range+0.0/+10.0 volts, ac single indicator 8th range+0.0/+250.0 volts, ac single indicator 9th range+0.0/+500.0 volts, ac single indicator 10th range+0.0/+4000.0 volts, ac single indicator 11th range+0.00/+0.25 volts, dc single indicator 12th range+0.0/+10.0 volts, dc single indicator 13th range+0.0/+250.0 volts, dc single indicator 14th range+0.0/+500.0 volts, dc single indicator 15th range+0.0/+4000.0 volts, dc single indicator 16th range
Measurement Range
+0.0 to 10.0 amperes, dc single indicator 1st range
Measurement Range
+0.0 to 10.0 volts, ac single indicator 8th range
Measurement Range
+0.0 to 10.0 volts, dc single indicator 13th range
Measurement Range
+0.0 to 100.0 milliamperes, dc single indicator 6th range
Measurement Range
+0.0 to 20.0 megohms single indicator 4th range
Measurement Range
+0.0 to 200.0 kilohms single indicator 3rd range
Measurement Range
+0.0 to 250.0 volts, ac single indicator 9th range
Measurement Range
+0.0 to 250.0 volts, dc single indicator 14th range
Measurement Range
+0.00 to 0.25 volts, dc single indicator 12th range
Measurement Range
+0.0 to 4000.0 volts, ac single indicator 11th range
Measurement Range
+0.0 to 4000.0 volts, dc single indicator 16th range
Measurement Range
+0.0 to 50.0 microamperes, dc single indicator 5th range
Measurement Range
+0.0 to 500.0 milliamperes, dc single indicator 7th range
Measurement Range
+0.0 to 500.0 volts, dc single indicator 15th range
Measurement Range
+0.0 to 500.0 volts, ac single indicator 10th range
Measurement Range
-20.0 to 50.0 decibels single indicator 2nd range
Scale Selection Method
Switch
Features Provided
Portable and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 probe, direct contact and 2 wire lead
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Portable
An instrument which is arranged to measure two or more different electrical quantities (such as volts, amps, and ohms) by means of associated circuits and switches. The value is usually expressed on a single calibrated dial or digital readout display. For items which are connected into a circuit and used chiefly to visually monitor an operation, see meter, multiple scale. See also counter, electronic, digital readout. Excludes bridge (as modified).