Model: 458D510G12

Circuit Breaker

Special Features:

Circuit breaker supplied with two threaded mounting screws

Properties:

Body Style
Multipole-single actuator type
Body Length
6.500 inches
Body Width
4.125 inches
Body Height
4.062 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
3.938 inches
Center To Center Distance Between Terminals Parallel To Width
1.375 inches
Unthreaded Mounting Hole Diameter
0.190 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.827 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.688 inches
Fragility Factor
Moderately rugged
Boss Height
0.188 inches
Pole Quantity
3
Arc Quenching Method
Air
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
7500.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Thermal-magnetic all locations
Trip Release Characteristic
Instantaneous all locations and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole two
Trip Delay Time In Seconds Per Rated Continuous Current
5.000 at 200 pct all locations and 15.000 at 200 pct all locations
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations
Frequency In Hertz
400.0 all locations
Test Data Document
81349-mil-c-17361 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity
6 quick disconnect, male
Specification Data
81349-mil-c-17361/4 government specification
NSN
5925-00-867-7329
Part Number
458D510G12
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part 458D510G12 NSN 5925-00-867-7329

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
MMAC:
CRITL:
X

Packaging & Shipping

Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
6.3000lbs
Item Weight:
--
Item Dim:
--
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
--
WCC:
658
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

End Items End applications NSN 5925-00-867-7329 is a component of

  • Cargo/weapons Elevators
  • Stream (std. Tensioned Replenishment At Sea Method)
  • Los Angeles Class Ssn (688)
  • Ticonderoga Class Cg (47)
  • Spruance Class Dd (963)
  • Forrestal Class Cv
  • Nimitz Class Cvn
  • Arleigh Burke Class Ddg
  • Oliver Perry Class Ffg

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-00-867-7329) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi

Highest Rated Parts
Recently Purchased Parts
Hot Parts