Model: 45-000PH4AMP

Circuit Breaker
Description:

Single pole type body style, 1.970 inches overall length, 0.730 inches overall width, plastic case material, 0.180 inches unthreaded mounting hole diameter.

Properties:

Body Style
Single pole type
Overall Length
1.970 inches
Overall Width
0.730 inches
Case Material
Plastic
Unthreaded Mounting Hole Diameter
0.180 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.570 inches
Boss Height
0.280 inches
Mounting Surface To Terminal End Distance
1.970 inches
Pole Quantity
1
Mounting Facility Type And Quantity
2 unthreaded hole
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac single location and 4.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 24.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
40.0 ac single location and 40.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Thermal single location
Trip Release Characteristic
Time delay single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 push button
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Internal Trip Release Configuration
Series trip single location
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 200 pct single location and 40.000 at 200 pct single location and 3.000 at 300 pct single location and 18.000 at 300 pct single location and 2.000 at 400 pct single location and 9.000 at 400 pct single location
Trip Release Ambient Tempurature Rating
20.0 degrees celsius single location
Terminal Type And Quantity
2 quick disconnect, male
NSN
5925-00-054-8656
Part Number
45-000PH4AMP
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part 45-000PH4AMP NSN 5925-00-054-8656

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
MMAC:
CRITL:
X

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
77.5
WCC:
659
TCC:
Z
SHC:
Z
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-00-054-8656) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi