Model: 44290-1
Band Pass Filter
Properties:
Overall Height
0.993 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.000 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.250 inches
Reference Frequency Per Function
26.0 single radio interference pulses per second
Reference Frequency Per Function
28.4 single radio interference two phase to two phase
Reference Frequency Per Function
30.8 single radio interference two phase to three phase
Reference Frequency Per Function
33.2 single radio interference hertz
Reference Frequency Per Function
35.6 single radio interference three phase to two phase
Reference Frequency Per Function
38.0 single radio interference gigahertz
Source Impedance Rating Per Function
1.0 ohms 6th band pass
Source Impedance Rating Per Function
1.0 ohms 1st band pass
Source Impedance Rating Per Function
1.0 ohms 2nd band pass
Source Impedance Rating Per Function
1.0 ohms 3rd band pass
Source Impedance Rating Per Function
1.0 ohms 4th band pass
Source Impedance Rating Per Function
1.0 ohms 5th band pass
Load Impedance Per Function
50.0 ohms 1st band pass
Load Impedance Per Function
50.0 ohms 3rd band pass
Load Impedance Per Function
50.0 ohms 2nd band pass
Load Impedance Per Function
50.0 ohms 6th band pass
Load Impedance Per Function
50.0 ohms 4th band pass
Load Impedance Per Function
50.0 ohms 5th band pass
Mounting Facility Screw Thread Series Designator
Unc
Mounting Facility Type And Quantity
12 threaded hole
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 4th band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 5th band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 6th band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 3rd band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
Functional Terminal Type And Quantity
1 pin input 1st function
Functional Terminal Type And Quantity
1 pin output 2nd function
Functional Terminal Type And Quantity
6 pin input-output/ground 3rd function
Specified Frequencies Of Discrimination Per Function
30.80 kilohertz 4th band pass 4th function and 33.10 kilohertz 4th band pass 4th function and 33.30 kilohertz 4th band pass 4th function and 35.60 kilohertz 4th band pass 4th function
Specified Frequencies Of Discrimination Per Function
33.20 kilohertz 5th band pass 5th function and 35.50 kilohertz 5th band pass 5th function and 35.70 kilohertz 5th band pass 5th function and 38.00 kilohertz 5th band pass 5th function
Specified Frequencies Of Discrimination Per Function
35.60 kilohertz 6th band pass 6th function and 37.90 kilohertz 6th band pass 6th function and 38.10 kilohertz 6th band pass 6th function and 43.00 kilohertz 6th band pass 6th function
Specified Frequencies Of Discrimination Per Function
22.80 kilohertz 1st band pass 1st function and 25.90 kilohertz 1st band pass 1st function and 26.10 kilohertz 1st band pass 1st function and 28.40 kilohertz 1st band pass 1st function
Specified Frequencies Of Discrimination Per Function
26.40 kilohertz 2nd band pass 2nd function and 28.30 kilohertz 2nd band pass 2nd function and 28.50 kilohertz 2nd band pass 2nd function and 30.80 kilohertz 2nd band pass 2nd function
Specified Frequencies Of Discrimination Per Function
28.40 kilohertz 3rd band pass 3rd function and 30.70 kilohertz 3rd band pass 3rd function and 30.90 kilohertz 3rd band pass 3rd function and 33.20 kilohertz 3rd band pass 3rd function
Frequency Band Width Per Function
25.90 kilohertz 1st band pass and 26.10 kilohertz 1st band pass
Frequency Band Width Per Function
28.30 kilohertz 2nd band pass and 28.50 kilohertz 2nd band pass
Frequency Band Width Per Function
30.70 kilohertz 3rd band pass and 30.90 kilohertz 3rd band pass
Frequency Band Width Per Function
33.10 kilohertz 4th band pass and 33.30 kilohertz 4th band pass
Frequency Band Width Per Function
35.50 kilohertz 5th band pass and 35.70 kilohertz 5th band pass
Frequency Band Width Per Function
37.90 kilohertz 6th band pass and 38.10 kilohertz 6th band pass
Discrimination At Specificationified Frequencies Per Function In Decibels
30.0 2nd band pass 2nd function and 3.0 2nd band pass 2nd function and 3.0 2nd band pass 2nd function and 30.0 2nd band pass 2nd function
Discrimination At Specificationified Frequencies Per Function In Decibels
30.0 3rd band pass 3rd function and 3.0 3rd band pass 3rd function and 3.0 3rd band pass 3rd function and 30.0 3rd band pass 3rd function
Discrimination At Specificationified Frequencies Per Function In Decibels
30.0 1st band pass 1st function and 3.0 1st band pass 1st function and 3.0 1st band pass 1st function and 30.0 1st band pass 1st function
Discrimination At Specificationified Frequencies Per Function In Decibels
30.0 6th band pass 6th function and 3.0 6th band pass 6th function and 3.0 6th band pass 6th function and 30.0 6th band pass 6th function
Discrimination At Specificationified Frequencies Per Function In Decibels
30.0 4th band pass 4th function and 3.0 4th band pass 4th function and 3.0 4th band pass 4th function and 30.0 4th band pass 4th function
Discrimination At Specificationified Frequencies Per Function In Decibels
30.0 5th band pass 5th function and 3.0 5th band pass 5th function and 3.0 5th band pass 5th function and 30.0 5th band pass 5th function
Body Surface Treatment
Tin
Style Designator
Rectangular terminal/terminals on one surface
Description
Filter,band Pass
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See coil (as modified); reactor; capacitor (as modified); and resistor (as modified).