Model: 321-18050-05

Transformer Assembly

Properties:

Reliability Indicator
Not established
Hazardous Locations/environmental Protection
Vibration resistant
Overall Length
6.030 inches
Overall Height
3.570 inches
Mounting Hole Diameter
0.500 inches 2nd group
Mounting Slot Width
0.187 inches 1st group
Frequency Rating
10.0 kilohertz all components
Input-output Phase Relationship
Single phase to single phase all components
Winding Shielding Method
Internal shield brought out to terminal 3rd component and internal shield grounded to core and brought out to terminal 3rd component
Winding Shielding Method
Internal shield brought out to terminal 2nd component
Body Width
3.440 inches
Maximum Operating Temp
130.0 degrees celsius
Distance Between Mounting Facility Centers
2.500 inches 2nd mounting facility single center group
Distance Between Mounting Facility Centers
4.500 inches 1st mounting facility single center group
Distance Between Mounting Facility Centers
5.375 inches 3rd mounting facility single center group
Mounting Tab Width
0.625 inches
Inclosure Type
Fully enclosed
Mounting Facility Quantity
2 1st group
Mounting Facility Quantity
2 2nd group
Mounting Method
Slot 1st group
Mounting Method
Tab 3rd group
Mounting Method
Unthreaded hole 2nd group
Rating Method
Electrical 1st component 4th secondary
Rating Method
Electrical 2nd component 4th secondary
Rating Method
Electrical all components 1st secondary
Rating Method
Electrical all components 2nd secondary
Rating Method
Electrical all components 3rd secondary
Rating Method
Electrical all components single primary
Winding Function And Quantity
1 primary 1st component and 4 secondary 1st component
Winding Function And Quantity
1 primary 2nd component and 4 secondary 2nd component
Winding Function And Quantity
1 primary 3rd component and 3 secondary 3rd component
Features Provided
W/rectifier
Winding Operating Current
0.01 amperes ac 3rd component 1st secondary
Winding Operating Current
0.035 amperes ac 3rd component 3rd secondary
Winding Operating Current
1.2 amperes dc 3rd component 2nd secondary
Winding Operating Current
35.0 milliamperes ac 2nd component 3rd secondary
Winding Operating Current
50.0 milliamperes ac 2nd component 2nd secondary
Winding Operating Current
50.0 milliamperes ac 2nd component 1st secondary
Winding Operating Current
3.0 amperes ac 2nd component 4th secondary
Winding Operating Current
30.0 milliamperes ac 1st component 4th secondary
Dc Resistance Rating In Ohms
0.040 3rd component single primary
Dc Resistance Rating In Ohms
0.060 1st component 2nd secondary
Dc Resistance Rating In Ohms
0.090 2nd component 4th secondary
Dc Resistance Rating In Ohms
0.100 3rd component 1st secondary
Dc Resistance Rating In Ohms
0.200 1st component 1st secondary
Dc Resistance Rating In Ohms
0.200 1st component 3rd secondary
Dc Resistance Rating In Ohms
0.200 1st component single primary
Dc Resistance Rating In Ohms
0.280 2nd component single primary
Dc Resistance Rating In Ohms
1.200 2nd component 1st secondary
Dc Resistance Rating In Ohms
12.000 2nd component 2nd secondary
Dc Resistance Rating In Ohms
2.750 1st component 4th secondary
Winding Power Rating
0.2 volts-amperes 3rd component 1st secondary
Winding Power Rating
159.07 volts-amperes 1st component 4th secondary
Winding Power Rating
160.2 volts-amperes 3rd component 2nd secondary
Winding Power Rating
18.03 volts-amperes 2nd component 4th secondary
Winding Power Rating
300.5 volts-amperes 2nd component 1st secondary
Winding Power Rating
3535.0 volts-amperes 2nd component 2nd secondary
Winding Power Rating
5245.8 volts-amperes 2nd component 3rd secondary
Winding Power Rating
7.47 volts-amperes 3rd component 3rd secondary
Winding Operating Voltage
106.05 ac volts 1st component single primary
Winding Operating Voltage
106.05 ac volts 1st component 1st secondary
Winding Operating Voltage
106.05 ac volts 1st component 3rd secondary
Winding Operating Voltage
130.00 dc volts 3rd component 2nd secondary and 137.00 dc volts 3rd component 2nd secondary
Winding Operating Voltage
14.14 ac volts 2nd component single primary
Winding Operating Voltage
149.88 ac volts 2nd component 3rd secondary
Winding Operating Voltage
15.55 ac volts 1st component 2nd secondary
Winding Operating Voltage
15.55 ac volts 3rd component single primary
Winding Operating Voltage
16.26 ac volts 3rd component 1st secondary
Winding Operating Voltage
178.16 ac volts 3rd component 3rd secondary and 195.84 ac volts 3rd component 3rd secondary and 213.57 ac volts 3rd component 3rd secondary
Winding Operating Voltage
70.70 ac volts 2nd component 2nd secondary
Winding Operating Voltage
530.25 ac volts 1st component 4th secondary
Winding Operating Voltage
6.01 ac volts 2nd component 1st secondary
Winding Operating Voltage
6.01 ac volts 2nd component 4th secondary
Terminal Type And Quantity
36 wire lead
NSN
5950-01-339-8204
Part Number
321-18050-05
Description
Transformer Assembly
CAGE

Two or more separable transformer (as modified) on a common mounting or mounted on each other.

Part 321-18050-05 NSN 5950-01-339-8204

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00449
FIIG:
A058B0
Concept No.:
App. Key:
T
Cond. Code:
2
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
MMAC:
CRITL:
X

Packaging & Shipping

Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
6.0 X 3.6 X 3.4
Paclk Weight:
5.0000lbs
Item Weight:
--
Item Dim:
--
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
OPI:
M
SPI No.:
J502114933
SPI Rev.:
SPC Mkg:
28
LVL_A:
Z
LVL_B:

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
063420
UFC:
35355
LTL:
RATING VARIABLE
LCL:
--
WCC:
595
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this transformer assembly (NSN 5950-01-339-8204) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8504900020
  • SITC: 77129
  • End Use: Generators, accessories
  • NAICS: 335311
  • USDA: 1

Freight Class: Transformer parts

Highest Rated Parts
Recently Purchased Parts
Hot Parts