Model: 203-111-2236-10

Circuit Breaker

Properties:

Body Style
Multipole-multiple actuator type
Body Length
Between 1.970 inches and 2.030 inches
Body Width
Between 1.915 inches and 1.945 inches
Body Height
Between 1.740 inches and 1.770 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Width
Between 0.595 inches and 0.655 inches
Boss Height
Between 0.095 inches and 0.125 inches
Pole Quantity
3
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
4 clip
Storage Type
General purpose warehouse
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic-hydraulic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Ultimate Trip Time Per Pole In Seconds
2.000 all locations and 60.000 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole two
External Actuator Linkage Arrangement
One, two, and three linked
Internal Trip Release Configuration
Series trip all locations
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 at 200 pct all locations and 9.000 at 200 pct all locations and 0.070 at 300 pct all locations and 0.300 at 300 pct all locations and 0.009 at 500 pct all locations and 0.900 at 500 pct all locations
Inclosure Protection Type For Which Designed
Fungus resistant
Frequency In Hertz
400.0 all locations
Terminal Type And Quantity
6 tab, solder lug
NSN
5925-01-080-5004
Part Number
203-111-2236-10
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part 203-111-2236-10 NSN 5925-01-080-5004

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
MMAC:
CRITL:
X

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
77.5
WCC:
658
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-01-080-5004) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi

Highest Rated Parts
Recently Purchased Parts
Hot Parts