Model: 144A9617P7
Radio Frequency Interfere Filter
Special Features:
Thirty-three filtered functions; four grounded contacts
Properties:
Overall Length
2.012 inches
Overall Height
1.219 inches
Overall Width
1.219 inches
Unthreaded Mounting Hole Diameter
Between 0.126 inches and 0.132 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.969 inches
Vibration Resistance Range In Hertz
+10.0/+500.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.969 inches
Operating Tempurature Range
-55.0/+125.0 degrees celsius
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
Load Impedance Per Function
50.0 ohms 1st radio interference
Load Impedance Per Function
50.0 ohms 3rd radio interference
Load Impedance Per Function
50.0 ohms 2nd radio interference
Load Impedance Per Function
50.0 ohms 6th radio interference
Load Impedance Per Function
50.0 ohms 4th radio interference
Load Impedance Per Function
50.0 ohms 5th radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 4th radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 5th radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 6th radio interference
Operating Current Rating Per Function In Amps
5.0 1st radio interference
Operating Current Rating Per Function In Amps
5.0 4th radio interference
Operating Current Rating Per Function In Amps
5.0 5th radio interference
Operating Current Rating Per Function In Amps
5.0 6th radio interference
Operating Current Rating Per Function In Amps
5.0 2nd radio interference
Operating Current Rating Per Function In Amps
5.0 3rd radio interference
Maximum Voltage Drop Per Function
1.2 volts ac 2nd radio interference and 2.0 volts dc 2nd radio interference
Maximum Voltage Drop Per Function
1.2 volts ac 3rd radio interference and 2.0 volts dc 3rd radio interference
Maximum Voltage Drop Per Function
1.2 volts ac 1st radio interference and 2.0 volts dc 1st radio interference
Maximum Voltage Drop Per Function
1.2 volts ac 4th radio interference and 2.0 volts dc 4th radio interference
Maximum Voltage Drop Per Function
1.2 volts ac 5th radio interference and 2.0 volts dc 5th radio interference
Maximum Voltage Drop Per Function
1.2 volts ac 6th radio interference and 2.0 volts dc 6th radio interference
Principal Circuitry Type Per Function
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function
Inductance-capacitance 5th radio interference
Principal Circuitry Type Per Function
Inductance-capacitance 6th radio interference
Input Terminal Manufacturer Code
71468
Input Terminal Identification
Mil-c-38999
Output Terminal Manufacturer Code
71468
Output Terminal Identification
Mil-c-38999
Maximum Tempurature Rise
25.0 degrees celsius
Full Load Insertion Loss Frequencies In Megahertz
0.1 and 1.0 and 10.0 and 100.0 and 500.0 and 1000.0
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels
2.0 and 10.0 and 40.0 and 75.0 and 90.0 and 90.0
Inclosure Type
Hermetically sealed
Mounting Facility Type And Quantity
4 unthreaded hole
Features Provided
Moisture resistant and shock resistant
Functional Terminal Type And Quantity
37 friction w/grounding strap and pin input-output
Maximum Dielectric Withstanding Ac Rms Voltage
300.0 volts at sea level
Operating Voltage Rating And Type Per Function
120.0 volts ac 1st radio interference 1st function and 200.0 volts dc 1st radio interference 1st function
Operating Voltage Rating And Type Per Function
120.0 volts ac 3rd radio interference 3rd function and 200.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function
120.0 volts ac 4th radio interference 4th function and 200.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function
120.0 volts ac 2nd radio interference 2nd function and 200.0 volts dc 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function
120.0 volts ac 5th radio interference 5th function and 200.0 volts dc 5th radio interference 5th function
Operating Voltage Rating And Type Per Function
120.0 volts ac 6th radio interference 6th function and 200.0 volts dc 6th radio interference 6th function
Maximum Dielectric Withstanding Dc Voltage
300.0 volts at sea level
Body Surface Treatment
Cadmium
Precious Material And Location
Contact surfaces gold
Style Designator
Filter connector
Description
Filter,radio Frequency Interfere
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes filter, low pass and suppressor, ignition interference. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see filter, band suppression and filter, band pass. See also limiter, electrical noise.