Model: 130377A

Circuit Breaker

Properties:

Body Style
Single pole type
Overall Length
2.000 inches
Body Width
1.188 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
Any acceptable
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Any acceptable
Mounting Surface To Terminal End Distance
1.281 inches
Pole Quantity
1
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
General purpose warehouse
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
600.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Thermal single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
Automatic
Internal Trip Release Configuration
Series trip single location
Thread Size
0.164 inches
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 at 200 pct single location and 60.000 at 200 pct single location
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 at 200 pct and 60.000 at 200 pct single location
Inclosure Protection Type For Which Designed
Dustproof and weatherproof
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location
Thread Series Designator
Unc
Terminal Type And Quantity
2 screw
NSN
5925-00-500-6753
Part Number
130377A
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part 130377A NSN 5925-00-500-6753

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
MMAC:
EH
CRITL:
X

Packaging & Shipping

Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
4.0 X 4.0 X 1.0
Paclk Weight:
0.1000lbs
Item Weight:
--
Item Dim:
--
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
--
WCC:
658
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-00-500-6753) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi