Model: 10182040

Circuit Breaker

Properties:

Body Style
Single pole type
Bushing Length
0.450 mils and 0.550 centimeters
Body Length
1.562 inches
Body Width
0.625 inches
Case Material
Metal
Mounting Surface To Terminal End Distance
1.700 inches
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Magnetic single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
Ultimate Trip Time Per Pole In Seconds
0.200 single location and 7.000 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Internal Trip Release Configuration
Series trip single location
Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.050 at 800 pct pascal single location and 0.950 18 stage pascal single location
Inclosure Protection Type For Which Designed
Moisture resistant
Test Data Document
18876-10182040 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
Unef
Terminal Type And Quantity
2 screw
NSN
5925-00-890-7487
Part Number
10182040
Description
Circuit Breaker
CAGE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Part 10182040 NSN 5925-00-890-7487

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Material Classification

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
MMAC:
CRITL:
X

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061300
UFC:
34410
LTL:
77.5
LCL:
77.5
WCC:
658
TCC:
Z
SHC:
9
ACC:
Instruments/Radio

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

How to Order  

Ordering from buyaircraftparts.com

If you would like to order this circuit breaker (NSN 5925-00-890-7487) please submit the pricing and availability form above to receive an up to date quote by email. If you agree to the pricing and terms you can e-sign your order online!

We are pleased to have the opportunity to serve you.

Have a Question

Hours: 08:00-18:00 Eastern Standard Time
Phone: +1 470-231-0824
Email: Contact Form »
Schedule B and Export
  • Schedule B: 8536200040
  • SITC: 77252
  • End Use: Electric apparatus
  • NAICS: 335313
  • USDA: 1

Freight Class: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi