NSN 5930-00-236-2351

Rotary Switch
DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
002362351

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

Inventory

 

This product may be available in the following quantities and conditions.

  • NS: 3
  • SV: 1
  • NE: 1

Please note that inventory for this NSN was updated 04/01/2025 and may have changed since then. Request a quote for up to date pricing and availability.

Product Definition Definition of approved item name (AIN): "SWITCH,ROTARY"

A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see switch, sensitive. Excludes relay, rotary; switch, stepping; and switch, telephone (as modified).

5930-00-236-2351 Spec. NSN part characteristics

MRC
Name
Detail
MRC:
AAJD
Thread Class
2a 1st mounting facility
MRC:
AASA
Thread Length
0.312 inches 1st mounting facility
MRC:
ABFE
Hazardous Locations/environmental Protection
Explosion proof
MRC:
ABHP
Overall Length
3.146 inches
MRC:
ABKW
Overall Height
1.500 inches
MRC:
ABMK
Overall Width
2.635 inches
MRC:
ABWV
Shaft Diameter
0.250 inches single actuator
MRC:
ABXF
Shaft Length
0.531 inches single actuator
MRC:
AEBV
Unthreaded Mounting Hole Diameter
0.200 inches 2nd mounting facility
MRC:
AFBH
Individual Section Quantity
4
MRC:
AFDC
Nonturn Device Type
Slotted bushing at 12: 00 o'clock
MRC:
AFDS
Longest Horizontal Distance Between Mounting Centers
1.360 inches 2nd mounting facility
MRC:
AGAV
End Application
Advanced air traffic control & land system (atcals) 404l. B-1b, f-4 phantom, t-39 aircraft. B-52 aircraft support equipment. An/tps-59 lightweight 3d radar set. 30 hz 1800 btu air condtiioner. Refridgeration systems. 60 hz 9000 btu air conditioner. 485l tacs.
MRC:
AJZE
Switch Contact Basic Design
Nonpile-up symmetrical
MRC:
AKPX
Pole Quantity
2 each section periphery
MRC:
AKPY
Throw Quantity
2 each section periphery
MRC:
AXGY
Mounting Method
Unthreaded hole 2nd mounting facility
MRC:
CQJX
Thread Size
0.375 inches 1st mounting facility
MRC:
CQMK
Contact Voltage Rating In Volts
250.0 highest ac voltage rating at sea level
MRC:
CQYJ
Mounting Facility Pattern
Two position in-line 2nd mounting facility
MRC:
CRJH
Switch Actuator Indexing Position Quantity
2 single actuator
MRC:
CRSJ
Shaft Type
Round single actuator
MRC:
CRTL
Criticality Code Justification
Feat
MRC:
CSCF
Terminal Type
Tab, solder lug
MRC:
CSHW
Contact Switching Action
Breaks before makes each section periphery
MRC:
CSLC
Switch Actuator Positioning Increment
45.0 degrees single actuator
MRC:
CTDN
Switch Actuator Stop Device Type
Fixed stop single actuator
MRC:
CTHF
Contact Load Current Rating
7.0 amperes inductive load lowest ac voltage rating at sea level
MRC:
FEAT
Special Features
Weapon system essential
MRC:
PMLC
Precious Material And Location
Contacts silver
MRC:
PRMT
Precious Material
Silver
MRC:
STYL
Style Designator
Square wafer, panel mount
MRC:
THSD
Thread Series Designator
Unf 1st mounting facility

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
8912K261
Cage Code:
81640
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
CT
Status:
A
MSDS:
SADC:
Part Number:
TIP00013
Cage Code:
97403
RNCC:
5
RNVC:
2
DAC:
3
RNAAC:
CT
Status:
A
MSDS:
SADC:
Part Number:
13216E6201-1
Cage Code:
97403
RNCC:
7
RNVC:
2
DAC:
A
RNAAC:
CT
Status:
A
MSDS:
SADC:
Part Number:
ROT-2113
Cage Code:
52401
RNCC:
5
RNVC:
2
DAC:
A
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
R63870D16E6201
Cage Code:
60144
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
CT
Status:
A
MSDS:
SADC:
Part Number:
2267A4
Cage Code:
70611
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
2267A1
Cage Code:
70611
RNCC:
5
RNVC:
9
DAC:
6
RNAAC:
CT
Status:
A
MSDS:
SADC:
Part Number:
E6201-2
Cage Code:
10391
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
13216E6201-2
Cage Code:
97403
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
5930002362351
Cage Code:
A00AM
RNCC:
6
RNVC:
9
DAC:
9
RNAAC:
YP
Status:
A
MSDS:
SADC:
Indicates a design/source control reference item
Inidicates part number has been superseded

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
02134
FIIG:
A052B0
Concept No.:
1
App. Key:
A
Cond. Code:
1
Status:
A

Special material and handling

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
S
ESD:
ESD:
ADPE:
CRITL:
Y
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) S

Item contains silver.

Criticality Y

The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restrictions or application.

Import and Export

Schedule B
NAIC
End Use
SITC
USDA
HITECH
Schedule B:
8536509025
NAICS:
335931
End Use Class:
20005
SITC:
77255
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8536509025

Switches, Rotary, Rated At Over 5 A, For A Voltage Not Exceeding 1, 000 Volts

End Use Code 20005

Electric Apparatus

Standard Intl. Trade Class (SITC) 77255

Switches For Electrical Apparatus, N.e.s., For Voltages Not Exceeding 1, 000 Volts

National motor freight and handling

NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
061300
NMF Description:
Circuit Breaker/switch Noi
UFC:
34410
LTL:
77.5
LCL:
--
WCC:
72D
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 72D

Communications/electronics, other than sigint/ew or comsec repair parts and components.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)